The repository has two SDKs for writing a CDAP device or bridge, three bridges built on the Python SDK, and the console has a flow builder. This page says what each one does today and how to start it. The messages they exchange with the gateway are on [CDAP protocol](https://docs.neode.sk/development/cdap-protocol.md); running the gateway and using the devices is on [CDAP devices](https://docs.neode.sk/console/cdap.md).

## What a device needs

- **The gateway's address**: `ws://<server-address>:21122/cdap`, or `wss://` with TLS on; see [The gateway](https://docs.neode.sk/console/cdap.md#the-gateway).
- **A credential**: an API key, a console account or a device token, as in [Signing in](https://docs.neode.sk/development/cdap-protocol.md#signing-in). An API key's or account's role needs **Approve enrollment**, which super admins, admins and global admins have by default; see [What each role can do](https://docs.neode.sk/people/users-and-roles.md#what-each-role-can-do). Keys come from the API, see [API keys](https://docs.neode.sk/development/api.md#api-keys).
- **A device ID** of 1 to 64 letters, digits, `-` and `_`. Neither SDK makes one up: without one, the Python SDK raises `ValueError` and the Node.js SDK throws.
- **A device type** the gateway takes: `scada`, `iot`, `os_agent`, `network`, `camera`, `desktop` or `custom`.

Both SDKs have the same example, a simulated greenhouse with a temperature, a humidity, a heater switch, a status text and a frost alert. It warms up while you switch the heater on in the console. The server's tests run both examples and the three bridges against a gateway, and CI runs them whenever the SDKs, the bridges or the gateway change.

## Python SDK

The package `neodesk_cdap` is in [`sdks/python`](https://github.com/neodeskapp/neodesk/tree/main/sdks/python). It needs Python 3.9 or newer and `websockets` 12 or newer. Install it from a checkout of the repository and start the example, with your server's address in place of `<server-address>` and a CDAP API key in place of `<api-key>`:

```bash
pip install ./sdks/python
CDAP_SERVER=ws://<server-address>:21122/cdap CDAP_API_KEY=<api-key> python sdks/python/examples/greenhouse.py
```

A small device with a temperature, a switch and an alert:

```python
import asyncio
import os

from neodesk_cdap import CDAPBridge, gauge, toggle

bridge = CDAPBridge(
    server="ws://<server-address>:21122/cdap",
    auth_method="api_key",
    api_key=os.environ["CDAP_API_KEY"],
    device_id="greenhouse-1",
    device_name="Greenhouse",
    device_type="iot",
)
bridge.add_widget(gauge("temp", "Temperature", unit="°C", min_val=-10, max_val=50))
bridge.add_widget(toggle("heater", "Heater"))
bridge.add_alert("frost", "temp < 2", label="Frost", message="Temperature is {temp} °C")

@bridge.on_command("heater")
async def heater(action, value, **kw):
    if action == "set":
        switch_heater(bool(value))  # your code
    return {"heater": bool(value)}

async def main():
    runner = asyncio.create_task(bridge.run_async())
    while True:
        await bridge.update_state("temp", read_temperature())  # your code
        await asyncio.sleep(10)

asyncio.run(main())
```

`bridge.run()` does the same as `run_async()` and blocks, for a device that only answers commands.

What the SDK does:

- **Connecting**: it asks for the subprotocol `cdap-v1` and signs in with `auth_method` `api_key` (`api_key`), `device_token` (`device_token`) or `user_password` (`username`, `password`). It has no field for a two-factor code. Then it registers a manifest built from the constructor (`device_name`, `device_type`, `vendor`, `model`, `firmware`, `tags`, `capabilities`, `heartbeat_sec`, and a bridge block when `bridge_name` is set, with `bridge_version` and `bridge_protocol`), the widgets and the alerts, and waits for the gateway to confirm it. `capabilities` is `["telemetry", "commands"]` unless you pass others.
- **Reconnecting**: after a lost or refused connection it waits `reconnect_sec` (5 by default), twice as long each time up to `max_reconnect` (300), plus up to a quarter more at random. It keeps trying after a refused sign-in or registration; the gateway's reason is in its log, the logger `neodesk_cdap`.
- **Values**: `update_state(id, value)` and `bulk_update({id: value, ...})` send values at once; both are coroutines to `await`. Values set before the device is registered are kept and go out with the first heartbeat. Every heartbeat, each `heartbeat_sec` seconds (15 by default, 5 to 300), sends again all values the SDK knows.
- **Commands**: `on_command("widget id")` registers a handler for one widget, `on_command()` one for all others. A handler may be a coroutine function or a plain function, and gets `action`, `value`, `widget_id`, `operator` and `reason` as keyword arguments. What it returns goes back as the result with status `ok`; an exception goes back as `error` with its message, and so does a command for a widget without a handler. After a `set` the SDK sends the new value at once, so the console shows the control's new state.
- **Alerts**: `add_alert(id, condition, label=, severity=, message=)` adds an alert to the manifest, as in [Alerts](https://docs.neode.sk/development/cdap-protocol.md#alerts). The gateway shows it under **Active alerts** while the condition holds. A device can't raise an alert any other way.
- **Logs**: `send_log(level, message, context)` sends a `log` message, with `level` `debug`, `info`, `warning`, `error` or `critical`.
- **Widgets**: `gauge`, `toggle`, `button`, `text_widget`, `led`, `slider`, `select`, `chart` and `table` build the widget types of the same names, each with a default `permissions` entry. `Widget(...)` takes every field of [Widgets](https://docs.neode.sk/development/cdap-protocol.md#widgets).

The [package README](https://github.com/neodeskapp/neodesk/blob/main/sdks/python/README.md) lists the methods.

## Node.js SDK

The package `neodesk-cdap` in [`sdks/nodejs`](https://github.com/neodeskapp/neodesk/tree/main/sdks/nodejs) is written in TypeScript and needs Node.js 22 or newer (22.18 or newer for the example, which Node runs as TypeScript). Build it and start the example, with your server's address in place of `<server-address>` and a CDAP API key in place of `<api-key>`:

```bash
cd sdks/nodejs
npm ci
npm run build
CDAP_SERVER=ws://<server-address>:21122/cdap CDAP_API_KEY=<api-key> node examples/greenhouse.mts
```

To use it in your project, run this there after the build, with the path of your checkout in place of `<checkout>`:

```bash
npm install <checkout>/sdks/nodejs
```

A small device:

```js
const { CDAPBridge, gauge, toggle } = require('neodesk-cdap');

const bridge = new CDAPBridge({
  server: 'ws://<server-address>:21122/cdap',
  apiKey: process.env.CDAP_API_KEY,
  deviceId: 'greenhouse-1',
  deviceName: 'Greenhouse',
  deviceType: 'iot',
});

bridge
  .addWidget(gauge('temp', 'Temperature', { unit: '°C', min: -10, max: 50 }))
  .addWidget(toggle('heater', 'Heater'))
  .addAlert('frost', 'temp < 2', { label: 'Frost', message: 'Temperature is {temp} °C' });

bridge.onCommand('heater', ({ value }) => {
  switchHeater(Boolean(value)); // your code
  return Boolean(value);
});
bridge.on('error', (err) => console.error(err.message));

bridge.run();
setInterval(() => bridge.updateState('temp', readTemperature()), 10000); // your code
```

It works like the Python SDK, with these differences:

- **Names**: `addWidget`, `addAlert`, `onCommand`, `updateState`, `bulkUpdate`, `sendLog`, `run` (a promise that reconnects until `stop()`), and `textWidget` for text.
- **Defaults**: `deviceType` is `custom`, `heartbeatSec` 15, `reconnectSec` 5 and `maxReconnect` 120. The manifest's capabilities are always `telemetry`, `commands`, `alerts` and `logs`.
- **Commands**: the handler gets the command (`command_id`, `widget_id`, `action`, `value`, `operator`, `reason`) and may return a value or a promise. What it returns goes back as the result and becomes the widget's value at once.
- **Events**: `connected`, `registered`, `command`, `disconnected`, `error`, `message`, and the type of any other message the server sends. Listen for `error`: as with any Node.js event emitter, an `error` event without a listener throws.

The [package README](https://github.com/neodeskapp/neodesk/blob/main/sdks/nodejs/README.md) has the details.

## Reference bridges

The bridges in [`bridges`](https://github.com/neodeskapp/neodesk/tree/main/bridges) are Python scripts on the Python SDK. Each reads a JSON config file: a `cdap` block for the connection (`server`, `api_key`, `device_id`, `device_name`, `device_type`, `bridge_name`, `heartbeat_sec`) and a block for the other side. `device_id` is required, and two bridges on one server need different ones. Without a `device_type` the Modbus bridge registers as `scada`, the SNMP bridge as `network` and the REST bridge as `iot`.

| Bridge | Script | Talks to | What it does |
|---|---|---|---|
| Modbus | `modbus/bridge_modbus.py` | Modbus TCP, or Modbus RTU over a serial port (`pymodbus` 3.10 or newer) | Reads holding and input registers, coils and discrete inputs every `poll_interval_sec`, as `int16`, `uint16`, `int32`, `uint32` or `float32` with `scale` and `offset`, and writes commands for entries that are not `readonly` back to the register or coil |
| SNMP | `snmp/bridge_snmp.py` | SNMP v2c or v3 (`pysnmp`) | Polls OIDs, shows time ticks and kilobytes readably, turns counters into rates, and applies a `transform` such as `100 - x` |
| REST and webhooks | `rest-webhook/bridge_rest.py` | HTTP (`aiohttp`) | Polls URLs and picks a value by a dotted path (the `jmespath` key), switches a toggle by calling a `write_url`, and listens for webhooks on `webhook_port` and `webhook_path` |

When the Modbus device or the REST API refuses a write, the bridge answers the command with an error and the control keeps its value.

A webhook entry of the REST bridge with `alert_severity` (`critical`, `warning` or `info`) adds an alert to the manifest. Once a matching webhook has set the entry's widget, the alert shows under **Active alerts** with `alert_message`, and it stays there until the bridge reconnects. Its `widget_id` has to start with a letter or `_` and hold only letters, digits, `_` and `.`.

To start one, install the SDK and the bridge's packages, copy the example config, set `server`, `api_key` and `device_id` in it and run the script with it:

```bash
pip install ./sdks/python
cd bridges/modbus
pip install -r requirements.txt
cp config.example.json config.json
python bridge_modbus.py --config config.json --log-level INFO
```

The [bridges README](https://github.com/neodeskapp/neodesk/blob/main/bridges/README.md) describes the config pattern.

## The flow builder

The console's **Flow builder (SDK)** page, at `/cdap-studio`, is an editor for data flows. The sidebar shows it to the operator role and to super admins.

- **Nodes**: you drag nodes from three groups onto the canvas and connect them. **Sources**: Modbus TCP, Modbus RTU, SNMP Poll, REST Poll, MQTT Subscribe, Webhook, Device Telemetry, Database Query, File Watch. **Processing**: Filter, Transform, Aggregate, Delay, Debounce, Switch, Merge, Script. **Outputs**: Widget Update, Alert, Command, Log, REST Call, MQTT Publish, Database Write, Email, Modbus Write. **Node settings** holds each node's settings.
- **Saving**: **Save flow** stores the flow on the server. Each flow belongs to the account that made it; super admins see and change all of them. **Open flow** lists the saved ones.
- **Templates**: five flows to start from: Temperature Monitor, SNMP Health Dashboard, REST API Aggregator, Modbus PLC Control and File Change Detector.
- **Test run**: the server answers with a made-up result for each node and the number of nodes and connections. Nothing of the flow runs.
- **Deploy**: marks the saved flow as deployed. Nothing on the server runs flows, so a deployed flow does nothing yet either.
- **Files**: under **More**, **Download as file** saves a saved flow as a `.bdflow` file (JSON), and **Import flow** reads one back.

To get values from a device into the console, use one of the SDKs or the protocol; the flow builder does not connect to anything.