CDAP is the server's protocol for devices that are not RustDesk clients: sensors, controllers, bridges to other systems and agents. A device opens a WebSocket to the gateway, signs in, sends a manifest with its values and controls, and then keeps the server up to date and answers commands. This page is for people who write such a device or bridge. Running the gateway and using the devices in the console is on CDAP devices, and ready-made clients are on CDAP SDKs and bridges.

The reference is the Go code in neodesk-server/cdap; its types name every field.

Connecting

The gateway listens on port 21122 (CDAP_PORT) at the path /cdap:

ws://desk.example.com:21122/cdap
wss://desk.example.com:21122/cdap

wss:// works when the server runs with CDAP_TLS=Y and a certificate; plain ws:// keeps working on the same port unless CDAP_TLS_REQUIRED=Y. The gateway runs unless Disable gateway on the IoT devices page, or CDAP_ENABLED=N while nothing is saved there, turned it off for the next start. See The gateway.

  • The gateway offers the WebSocket subprotocol cdap-v1. Ask for it or for none. A client that asks only for another one gets no subprotocol back, and most WebSocket libraries then drop the connection.
  • Messages are JSON in text frames. Binary frames are only for desktop frames (see Sessions). One message may be up to 8 MiB.
  • Each connection and each sign-in counts against CDAP_RATE_LIMIT per address and minute, 30 by default. Above it the gateway answers 429 instead of opening the WebSocket, or refuses the sign-in. An address on the server's blocklist gets 403.
  • A browser page on another host needs its origin in WS_ALLOWED_ORIGINS. Agents that send no Origin header are not affected.
  • GET /cdap/health on the same port answers {"status": "ok", "connections": 3, "total": 41, "version": "..."} without signing in.

Messages

Every message has the same frame:

{"type": "state_update", "timestamp": "2026-11-22T10:15:00Z", "payload": {"widget_id": "temp", "value": 21.5}}

type and payload are required. The server fills timestamp (RFC 3339, UTC) on what it sends and doesn't need it on what it gets. id carries the command ID on commands and the session ID on session starts.

A connection goes through three steps:

  1. Sign in: the first message is auth, within 30 seconds.
  2. Register: the second message is register, within 30 seconds.
  3. From then on, both sides send the messages below until one closes the connection.

When step 1 fails, the server sends an error with code 1001 and the reason, and closes. When step 2 fails, it sends an error with code 2001 and closes.

Signing in

{
  "type": "auth",
  "payload": {
    "method": "api_key",
    "key": "3f1c9a20...",
    "device_id": "greenhouse-1",
    "client_version": "1.0.0"
  }
}
Field Used with What it is
method all api_key, user_password or device_token
device_id all The ID the device registers under: 1 to 64 letters, digits, - and _. Required
key api_key An API key of the server
username, password user_password A console account
totp_code user_password The current code, for an account with two-factor sign-in
token device_token A device token bound to this device
client_version all Optional
  • api_key: the device acts with the key's role. An expired key is refused. Keys are made through the API; see API keys.
  • user_password: the device acts with the account's role. For an account with two-factor sign-in the code goes in totp_code of the same message; without it the server answers 2fa_required and closes. After 5 failed password sign-ins within 5 minutes for one account, or from one address, the gateway refuses that account or address until the 5 minutes have passed.
  • device_token: the token has to be active and bound to exactly this device_id, and the device has to be on the server already and not banned, disabled or deleted. Tokens are bound to IDs of 6 to 16 characters; see Device tokens.

With api_key or user_password the device enrolls itself, so the role needs the Approve enrollment permission, as How a device signs in explains.

The answer:

{"type": "auth_result", "payload": {"success": true, "token": "eyJhbGciOi...", "role": "admin", "device_id": "greenhouse-1", "session_token": "..."}}

token is valid as long as an API sign-in token (24 hours by default) and can be renewed with token_refresh. A device needs it for nothing else in this protocol.

Registering

{
  "type": "register",
  "payload": {
    "manifest": {
      "manifest_version": "1.0",
      "device": {"name": "Greenhouse", "type": "iot", "firmware": "2.1.0", "tags": ["site-a"]},
      "capabilities": ["telemetry", "commands"],
      "heartbeat_interval": 15,
      "widgets": [
        {"id": "temp", "type": "gauge", "label": "Temperature", "unit": "°C", "min": -10, "max": 50},
        {"id": "heater", "type": "toggle", "label": "Heater", "group": "Controls"}
      ],
      "alerts": [
        {"id": "frost", "label": "Frost", "severity": "warning", "condition": "temp < 2", "message": "Temperature is {temp} °C"}
      ]
    }
  }
}

The server refuses the registration when the ID is banned, or when another account or API key registered the ID before (a device token is bound to its device and is exempt). A second connection with the same ID replaces the first one, which the server closes with code 4001.

The answer is {"type": "registered", "payload": {"device_id": "greenhouse-1", "server_time": "..."}}. The device now shows in the device list: the manifest's name as its host name, its type, tags and linked device, and as its user the account, apikey:<key-name> or device:<id>. When the device disconnects, the server marks it offline and drops the stored manifest.

The manifest

Field What the server takes
manifest_version 1.0, or empty for 1.0. Anything else is refused
device.name Required, up to 128 characters
device.type scada, iot, os_agent, network, camera, desktop or custom; empty means custom, anything else is refused
device.vendor, model, firmware, serial, location, icon, description Optional text
device.tags Up to 20 tags of up to 64 characters
device.linked_peer_id The ID of a device in the device list that belongs to this one
bridge.name, version, protocol, target_host, target_port Optional, for a bridge; the server stores protocol as the device's operating system and version as its version
capabilities Any of telemetry, commands, terminal, alerts, logs, remote_desktop, video_stream, audio, clipboard, file_transfer, input_control, keyboard_input, mouse_input, multi_monitor, unattended_access. An unknown one is refused
heartbeat_interval Seconds between heartbeats: 15 when missing, at most 300
widgets Up to 200, see below
alerts Up to 200, see below

Widgets

Each widget needs an id (up to 64 characters, unique in the manifest) and a type: toggle, gauge, button, led, chart, select, slider, text, table, terminal, desktop, video_stream, file_browser or audio. label defaults to the ID. The other fields are optional:

Fields For
group, value (the first value), readonly All widgets
unit, min, max, step, precision, warning_low, warning_high Gauges and sliders
confirm, confirm_message, style, icon, cooldown (seconds) Buttons
options: [{"label": "Auto", "value": "auto"}] Lists
chart_type, points, series: [{"id", "label", "color", "unit"}], retention Charts
columns: [{"id", "label", "type"}], max_rows, sortable Tables
permissions: {"read", "control", "execute"} All widgets, see below

Widget permissions

A command names an action, and the widget's permissions say which role it needs: query needs read, execute needs execute, and set, trigger, reset and any other action need control. Each takes viewer, operator or admin. Without a value, read is viewer and control and execute are operator; for terminal, desktop and file_browser widgets control and execute are admin.

The roles rank viewer, operator, admin. Server admins and global admins rank between operator and admin, and super admins count as admin. A command also needs the Send CDAP commands permission.

Alerts

An alert in the manifest fires while its condition holds and clears when it no longer does. The server checks every alert each time a value changes.

  • severity is critical, warning or info.
  • condition is <widget-id> <operator> <value>, with ==, !=, >, <, >= or <=. The widget ID there has to start with a letter or _ and hold only letters, digits, _ and .. When both sides are numbers they are compared as numbers (true and false count as 1 and 0). Otherwise only == and != work, comparing the text without regard to case; quotes around the value are optional. A condition the server can't read, or a widget without a value yet, doesn't fire.
  • message may hold {widget id}, which the server replaces with the current value.

Firing alerts show under Active alerts on the device's page and in GET /api/cdap/alerts, and each change is an event on the API's event stream. They clear when the device disconnects.

From the device

Type Payload What the server does
heartbeat metrics ({"cpu", "memory", "disk"}), widget_values ({"temp": 21.5}), both optional Keeps the device online, stores the metrics when one of them is above 0 and the values, and answers ping with server_time
state_update widget_id, value Stores one value
bulk_update updates: [{"widget_id", "value"}] Stores several values
command_response command_id, status, result, error_message, execution_time_ms Records the answer to a command
event event_type, data Passes it on as a cdap_event event
log level, message, context Passes it on as a cdap_log event; error and critical also go to the server log
help_request message, hostname Adds a request under Help requests, with the first 2048 characters of the message, and answers help_request_ack with its id
chat_message text, to_id Stores the first 4096 characters as a chat message from the device and answers chat_message_ack with its id
token_refresh {} Answers token_refreshed with a new token and expires_at
unregister reason Closes the connection

The heartbeat is what keeps the connection: a device that sends none for three heartbeat intervals, and at least 60 seconds, is closed with "heartbeat timeout". Other messages don't count.

The server keeps a value only for a widget of the manifest, and only when it takes at most 64 KiB as JSON; it drops other values without an answer. The console's device page reads the values every 3 seconds.

Errors

An error from the server is {"type": "error", "payload": {"code": 3003, "message": "widget_id is required"}}. After 1001 and 2001 the server closes the connection; after the others it carries on.

Code Meaning
1001 Sign-in failed
2001 Registration failed
1003 token_refresh with a token that is no longer valid
1006 Unknown message type
3001 to 3009 A payload the server can't read: 3001 heartbeat, 3002 state_update, 3003 state_update without widget_id, 3004 bulk_update, 3005 command_response, 3006 event, 3007 log, 3008 help_request or token_refresh, 3009 chat_message
5001, 5002 The server could not store a help request or a new token (5001) or a chat message (5002)

From the server

Type Payload When
command command_id, widget_id, action, value, operator, reason Someone used a control in the console or the API sent a command
ping server_time The answer to each heartbeat
chat_message from_id, from_name, text A console user wrote to the device
revoke reason The device was revoked; the server then closes with code 4003
error code, message See above

The console sends set with the new value for toggles, sliders and lists, and trigger without a value for buttons; the API also takes execute, reset and query. POST /api/peers/<id>/exec reaches a CDAP device as a command for the widget shell with the action run and the value {"command": "..."}.

Answer every command with a command_response that carries its command_id, and a status such as ok or error:

{"type": "command_response", "payload": {"command_id": "cmd_greenhouse-1_17", "status": "ok", "result": {"heater": true}, "execution_time_ms": 12}}

The server writes the answer to the audit log and passes it on as a cdap_command_response event. The console reads a control's state from the device's values, so send the new value with state_update after a change.

Sessions

The console opens terminal, file, desktop, video and audio sessions with a device. Each starts with a *_start message whose session_id is also in the frame's id; every later message of the session carries the session_id. The server opens a session only when the manifest has the capability for it, and ignores a device's message for a session that belongs to another device.

Session Capability Server sends Device sends
Terminal terminal or commands terminal_start (cols, rows, operator_name), terminal_input (data), terminal_resize (cols, rows), terminal_end terminal_output (data, stream: stdout or stderr), terminal_end (reason)
Files file_transfer file_start, then file_list, file_read, file_write and file_delete as the console sends them, file_end file_list_response, file_read_response, file_write_response, file_delete_response, file_end
Desktop remote_desktop desktop_start (width, height, quality, fps, fps_mode, codecs, video_codec, operator_name), desktop_input, desktop_control, desktop_resize, clipboard_set, codec_offer, key_exchange, keyframe_request, monitor_select, quality_adjust, desktop_end desktop_frame or binary frames, desktop_meta, monitor_list, codec_answer, cursor_update, key_exchange, clipboard_update, desktop_input_error, desktop_consent_denied, desktop_end
Video video_stream video_start (stream_id, quality, fps), video_end video_frame (format, width, height, data, timestamp, key_frame), video_end
Audio audio audio_start (codec, sample_rate, channels, direction), audio_input, audio_end audio_frame (codec, data, timestamp, duration, sequence), audio_end
  • The file requests carry request_id and path, reads also offset and length, writes data in base64, offset and done. The server passes the console's request on unchanged and the device's answer back; answers carry session_id and request_id. Keep file access inside a folder the device's owner chose.
  • desktop_frame carries format (jpeg, png or raw), width, height, data in base64 and timestamp in milliseconds. A binary frame is faster: 64 bytes of session ID, padded with zero bytes, then the frame itself, which the server passes to the browser as it is. desktop_meta (format, width, height, binary, codec_string) tells the browser how to decode the stream.
  • desktop_input has a type (mouse_move, mouse_down, mouse_up, mouse_scroll, key_press, key_release or text) with x, y, button, delta_x, delta_y, key, code, modifiers or text.
  • clipboard_update has format (text, image or html) and data.
  • For a device of type os_agent, or tagged support-agent, desktop_start also carries a session_grant signed with the server's key, valid for 5 minutes, which a support agent checks before it asks the person at the device for consent.

Type to search every page and section.