Copy as MarkdownThe repository has two SDKs for writing a CDAP device or bridge, three bridges built on the Python SDK, and the console has a flow builder. This page says what each one does today and how to start it. The messages they exchange with the gateway are on CDAP protocol; running the gateway and using the devices is on CDAP devices.
What a device needs
- The gateway's address:
ws://<server-address>:21122/cdap, orwss://with TLS on; see The gateway. - A credential: an API key, a console account or a device token, as in Signing in. An API key's or account's role needs Approve enrollment, which super admins, admins and global admins have by default; see What each role can do. Keys come from the API, see API keys.
- A device ID of 1 to 64 letters, digits,
-and_. Neither SDK makes one up: without one, the Python SDK raisesValueErrorand the Node.js SDK throws. - A device type the gateway takes:
scada,iot,os_agent,network,camera,desktoporcustom.
Both SDKs have the same example, a simulated greenhouse with a temperature, a humidity, a heater switch, a status text and a frost alert. It warms up while you switch the heater on in the console. The server's tests run both examples and the three bridges against a gateway, and CI runs them whenever the SDKs, the bridges or the gateway change.
Python SDK
The package neodesk_cdap is in sdks/python. It needs Python 3.9 or newer and websockets 12 or newer. Install it from a checkout of the repository and start the example, with your server's address in place of <server-address> and a CDAP API key in place of <api-key>:
pip install ./sdks/python
CDAP_SERVER=ws://<server-address>:21122/cdap CDAP_API_KEY=<api-key> python sdks/python/examples/greenhouse.pyA small device with a temperature, a switch and an alert:
import asyncio
import os
from neodesk_cdap import CDAPBridge, gauge, toggle
bridge = CDAPBridge(
server="ws://<server-address>:21122/cdap",
auth_method="api_key",
api_key=os.environ["CDAP_API_KEY"],
device_id="greenhouse-1",
device_name="Greenhouse",
device_type="iot",
)
bridge.add_widget(gauge("temp", "Temperature", unit="°C", min_val=-10, max_val=50))
bridge.add_widget(toggle("heater", "Heater"))
bridge.add_alert("frost", "temp < 2", label="Frost", message="Temperature is {temp} °C")
@bridge.on_command("heater")
async def heater(action, value, **kw):
if action == "set":
switch_heater(bool(value)) # your code
return {"heater": bool(value)}
async def main():
runner = asyncio.create_task(bridge.run_async())
while True:
await bridge.update_state("temp", read_temperature()) # your code
await asyncio.sleep(10)
asyncio.run(main())bridge.run() does the same as run_async() and blocks, for a device that only answers commands.
What the SDK does:
- Connecting: it asks for the subprotocol
cdap-v1and signs in withauth_methodapi_key(api_key),device_token(device_token) oruser_password(username,password). It has no field for a two-factor code. Then it registers a manifest built from the constructor (device_name,device_type,vendor,model,firmware,tags,capabilities,heartbeat_sec, and a bridge block whenbridge_nameis set, withbridge_versionandbridge_protocol), the widgets and the alerts, and waits for the gateway to confirm it.capabilitiesis["telemetry", "commands"]unless you pass others. - Reconnecting: after a lost or refused connection it waits
reconnect_sec(5 by default), twice as long each time up tomax_reconnect(300), plus up to a quarter more at random. It keeps trying after a refused sign-in or registration; the gateway's reason is in its log, the loggerneodesk_cdap. - Values:
update_state(id, value)andbulk_update({id: value, ...})send values at once; both are coroutines toawait. Values set before the device is registered are kept and go out with the first heartbeat. Every heartbeat, eachheartbeat_secseconds (15 by default, 5 to 300), sends again all values the SDK knows. - Commands:
on_command("widget id")registers a handler for one widget,on_command()one for all others. A handler may be a coroutine function or a plain function, and getsaction,value,widget_id,operatorandreasonas keyword arguments. What it returns goes back as the result with statusok; an exception goes back aserrorwith its message, and so does a command for a widget without a handler. After asetthe SDK sends the new value at once, so the console shows the control's new state. - Alerts:
add_alert(id, condition, label=, severity=, message=)adds an alert to the manifest, as in Alerts. The gateway shows it under Active alerts while the condition holds. A device can't raise an alert any other way. - Logs:
send_log(level, message, context)sends alogmessage, withleveldebug,info,warning,errororcritical. - Widgets:
gauge,toggle,button,text_widget,led,slider,select,chartandtablebuild the widget types of the same names, each with a defaultpermissionsentry.Widget(...)takes every field of Widgets.
The package README lists the methods.
Node.js SDK
The package neodesk-cdap in sdks/nodejs is written in TypeScript and needs Node.js 22 or newer (22.18 or newer for the example, which Node runs as TypeScript). Build it and start the example, with your server's address in place of <server-address> and a CDAP API key in place of <api-key>:
cd sdks/nodejs
npm ci
npm run build
CDAP_SERVER=ws://<server-address>:21122/cdap CDAP_API_KEY=<api-key> node examples/greenhouse.mtsTo use it in your project, run this there after the build, with the path of your checkout in place of <checkout>:
npm install <checkout>/sdks/nodejsA small device:
const { CDAPBridge, gauge, toggle } = require('neodesk-cdap');
const bridge = new CDAPBridge({
server: 'ws://<server-address>:21122/cdap',
apiKey: process.env.CDAP_API_KEY,
deviceId: 'greenhouse-1',
deviceName: 'Greenhouse',
deviceType: 'iot',
});
bridge
.addWidget(gauge('temp', 'Temperature', { unit: '°C', min: -10, max: 50 }))
.addWidget(toggle('heater', 'Heater'))
.addAlert('frost', 'temp < 2', { label: 'Frost', message: 'Temperature is {temp} °C' });
bridge.onCommand('heater', ({ value }) => {
switchHeater(Boolean(value)); // your code
return Boolean(value);
});
bridge.on('error', (err) => console.error(err.message));
bridge.run();
setInterval(() => bridge.updateState('temp', readTemperature()), 10000); // your codeIt works like the Python SDK, with these differences:
- Names:
addWidget,addAlert,onCommand,updateState,bulkUpdate,sendLog,run(a promise that reconnects untilstop()), andtextWidgetfor text. - Defaults:
deviceTypeiscustom,heartbeatSec15,reconnectSec5 andmaxReconnect120. The manifest's capabilities are alwaystelemetry,commands,alertsandlogs. - Commands: the handler gets the command (
command_id,widget_id,action,value,operator,reason) and may return a value or a promise. What it returns goes back as the result and becomes the widget's value at once. - Events:
connected,registered,command,disconnected,error,message, and the type of any other message the server sends. Listen forerror: as with any Node.js event emitter, anerrorevent without a listener throws.
The package README has the details.
Reference bridges
The bridges in bridges are Python scripts on the Python SDK. Each reads a JSON config file: a cdap block for the connection (server, api_key, device_id, device_name, device_type, bridge_name, heartbeat_sec) and a block for the other side. device_id is required, and two bridges on one server need different ones. Without a device_type the Modbus bridge registers as scada, the SNMP bridge as network and the REST bridge as iot.
| Bridge | Script | Talks to | What it does |
|---|---|---|---|
| Modbus | modbus/bridge_modbus.py |
Modbus TCP, or Modbus RTU over a serial port (pymodbus 3.10 or newer) |
Reads holding and input registers, coils and discrete inputs every poll_interval_sec, as int16, uint16, int32, uint32 or float32 with scale and offset, and writes commands for entries that are not readonly back to the register or coil |
| SNMP | snmp/bridge_snmp.py |
SNMP v2c or v3 (pysnmp) |
Polls OIDs, shows time ticks and kilobytes readably, turns counters into rates, and applies a transform such as 100 - x |
| REST and webhooks | rest-webhook/bridge_rest.py |
HTTP (aiohttp) |
Polls URLs and picks a value by a dotted path (the jmespath key), switches a toggle by calling a write_url, and listens for webhooks on webhook_port and webhook_path |
When the Modbus device or the REST API refuses a write, the bridge answers the command with an error and the control keeps its value.
A webhook entry of the REST bridge with alert_severity (critical, warning or info) adds an alert to the manifest. Once a matching webhook has set the entry's widget, the alert shows under Active alerts with alert_message, and it stays there until the bridge reconnects. Its widget_id has to start with a letter or _ and hold only letters, digits, _ and ..
To start one, install the SDK and the bridge's packages, copy the example config, set server, api_key and device_id in it and run the script with it:
pip install ./sdks/python
cd bridges/modbus
pip install -r requirements.txt
cp config.example.json config.json
python bridge_modbus.py --config config.json --log-level INFOThe bridges README describes the config pattern.
The flow builder
The console's Flow builder (SDK) page, at /cdap-studio, is an editor for data flows. The sidebar shows it to the operator role and to super admins.
- Nodes: you drag nodes from three groups onto the canvas and connect them. Sources: Modbus TCP, Modbus RTU, SNMP Poll, REST Poll, MQTT Subscribe, Webhook, Device Telemetry, Database Query, File Watch. Processing: Filter, Transform, Aggregate, Delay, Debounce, Switch, Merge, Script. Outputs: Widget Update, Alert, Command, Log, REST Call, MQTT Publish, Database Write, Email, Modbus Write. Node settings holds each node's settings.
- Saving: Save flow stores the flow on the server. Each flow belongs to the account that made it; super admins see and change all of them. Open flow lists the saved ones.
- Templates: five flows to start from: Temperature Monitor, SNMP Health Dashboard, REST API Aggregator, Modbus PLC Control and File Change Detector.
- Test run: the server answers with a made-up result for each node and the number of nodes and connections. Nothing of the flow runs.
- Deploy: marks the saved flow as deployed. Nothing on the server runs flows, so a deployed flow does nothing yet either.
- Files: under More, Download as file saves a saved flow as a
.bdflowfile (JSON), and Import flow reads one back.
To get values from a device into the console, use one of the SDKs or the protocol; the flow builder does not connect to anything.